Warning: include() [function.include]: URL file-access is disabled in the server configuration in /home/dra6510/public_html/standards/articles/0504_NumberedLayering.php on line 8

Warning: include(http://www.draftsperson.net/dtemplates/1top.tpl) [function.include]: failed to open stream: no suitable wrapper could be found in /home/dra6510/public_html/standards/articles/0504_NumberedLayering.php on line 8

Warning: include() [function.include]: Failed opening 'http://www.draftsperson.net/dtemplates/1top.tpl' for inclusion (include_path='.:/usr/local/lib/php/PEAR:/usr/lib/php:/usr/local/lib/php') in /home/dra6510/public_html/standards/articles/0504_NumberedLayering.php on line 8

Standards


Warning: include() [function.include]: URL file-access is disabled in the server configuration in /home/dra6510/public_html/standards/articles/0504_NumberedLayering.php on line 14

Warning: include(http://www.draftsperson.net/dtemplates/2top.tpl) [function.include]: failed to open stream: no suitable wrapper could be found in /home/dra6510/public_html/standards/articles/0504_NumberedLayering.php on line 14

Warning: include() [function.include]: Failed opening 'http://www.draftsperson.net/dtemplates/2top.tpl' for inclusion (include_path='.:/usr/local/lib/php/PEAR:/usr/lib/php:/usr/local/lib/php') in /home/dra6510/public_html/standards/articles/0504_NumberedLayering.php on line 14

Warning: include() [function.include]: URL file-access is disabled in the server configuration in /home/dra6510/public_html/standards/articles/0504_NumberedLayering.php on line 18

Warning: include(http://www.draftsperson.net/dtemplates/3column_one.tpl) [function.include]: failed to open stream: no suitable wrapper could be found in /home/dra6510/public_html/standards/articles/0504_NumberedLayering.php on line 18

Warning: include() [function.include]: Failed opening 'http://www.draftsperson.net/dtemplates/3column_one.tpl' for inclusion (include_path='.:/usr/local/lib/php/PEAR:/usr/lib/php:/usr/local/lib/php') in /home/dra6510/public_html/standards/articles/0504_NumberedLayering.php on line 18

Numbered CAD Layering System

April 2005

Written with the use of AutoCAD in mind, however principles apply to other CAD packages.

Core concepts

All layer names are prefix with a predefined set of numbers is the core of the concept behind this system. The first digit represents the discipline and the following digits refer to the object type (doors, columns etc.).

Benefits

  • Multiple drafters can work together on the same projects because the layer list is ordered and structured.
  • In theory elements from different disciplines can be drawn in a single file - In practice XREF-ing to individual files may be easier to manage.
  • The preset numbering of the layers allows for CAD programs to filter and manipulate the drawing easier. A program can search for those set parameters.

    Execution

    The layer naming can be just the numbers or with the following extensions:

  • X = eXisting: the objects drawn are existing conditions
  • D = Demolition: the objects drawn have to be demolished
  • N = Non-structural: both Architectural and Structural may require the use of this, for example, defining the structural and non-structural walls.
  • P = Proposed: Generally drawings are for proposed works anyway, however there may occur cases where it may be necessary to make the distinction.
  • -description = the dash and description can be used on all layers; example 105-room names, 105X-room names.

    Combinded Disciplines - sample list

    Layer No.

    Description

    Layer No.

    Description

    000

    Hatch boundary

    410

    Hardware

    001

    All general linework

    420

    Paving

    021

    Title sheet

    439

    Access Floors

    030

    Dimensions

    440

    Base layer for Xrefs

    032

    Room names

    444

    Partitions

    033

    Room numbers

    450

    Roofing

    034

    Floor finishes

    459

    Suspended ceilings

    035

    Detail reference no.

    460

    Curtain walls

    036

    Section reference no.

    461

    Windows

    037

    General Arch Text

    465

    Doors

    038

    General Struct Text

    510

    Cladding

    039

    Amendments/Revisions

    552

    Tiling

    040

    Grids

    553

    Resilient Finishes

    050

    Levels

    560

    Plastering

    051

    Contours

    570

    Painting

    060

    Symbols

    580

    Graphics, Artwork

    062

    Hatch Patterns

    591

    Carpets

    072

    Site Features (kerbs, manholes etc.)

    610

    Loose Furniture

    140

    Vegetation (Trees etc.

    611

    Furniture

    210

    Groundworks

    615

    Furniture Text

    215

    Piling

    722

    Stormwater

    220

    Concrete

    730

    Sanitary Services

    230

    Masonry Walls

    737

    Plumbing Fixtures

    235

    Stonework

    740

    Water Services

    250

    Structural Steel

    783

    Fire Protection-Sprinklers

    260

    Metalwork

    884

    Fans (ceiling and exhaust etc.)

    270

    Woodwork

    922

    Roadworks

    280

    Glazing

    700

    Hydraulics

    709

    General Hydraulic Text

    725

    Toxic Wastes

    720

    Drainage

    727

    Sewer Treatment

    728

    Special Services

    740

    Water Services

    741

    External services - mains

    742

    Cold Water Supply

    743

    Hot Water Supply

    745

    Chilled Water

    747

    Irrigation

    880

    Air Handling Ductwork

    749

    Condensaed Water System

    887

    Exhaust Systems

    780

    Fire Protection

    828

    Lights

    787

    Fire and Smoke Detection

    892

    Lifts

    791

    Voice and Data

    892

    Lifts

    800

    General Electrical

    846

    Security Systems


    Warning: include() [function.include]: URL file-access is disabled in the server configuration in /home/dra6510/public_html/standards/articles/0504_NumberedLayering.php on line 306

    Warning: include(http://www.draftsperson.net/dtemplates/4column_three.tpl) [function.include]: failed to open stream: no suitable wrapper could be found in /home/dra6510/public_html/standards/articles/0504_NumberedLayering.php on line 306

    Warning: include() [function.include]: Failed opening 'http://www.draftsperson.net/dtemplates/4column_three.tpl' for inclusion (include_path='.:/usr/local/lib/php/PEAR:/usr/lib/php:/usr/local/lib/php') in /home/dra6510/public_html/standards/articles/0504_NumberedLayering.php on line 306

    Warning: include() [function.include]: URL file-access is disabled in the server configuration in /home/dra6510/public_html/standards/articles/0504_NumberedLayering.php on line 310

    Warning: include(http://www.draftsperson.net/dtemplates/5bottom.tpl) [function.include]: failed to open stream: no suitable wrapper could be found in /home/dra6510/public_html/standards/articles/0504_NumberedLayering.php on line 310

    Warning: include() [function.include]: Failed opening 'http://www.draftsperson.net/dtemplates/5bottom.tpl' for inclusion (include_path='.:/usr/local/lib/php/PEAR:/usr/lib/php:/usr/local/lib/php') in /home/dra6510/public_html/standards/articles/0504_NumberedLayering.php on line 310