Drafters Forum | JOBS | Drafting Standards | Funnies | Technical Dictionary | AutoCAD Tutorials | Free Lisp | Free Blocks

ARTICLE: Top ways drafters can make money online with Freelancer.com

Concrete Reinforcing Tips for Australian Detailers

From Draftsperson.net

Revision as of 00:41, 21 May 2007; view current revision
←Older revision | Newer revision→

Contents

From the Code - AS 3600

Section 8.2.12.2

Shear reinforcment The maximum transverse spacing across the width of the member shall not exceed the lesser of 600mm and D (depth)

Section 8.6.3

side face bars For crack control in the side face of beams where the overall depth exceeds 750mm, longitudinal reinforcement, consisting of 12mm bars at 200mm centres, or 16mm bars at 300mm centres, shall be placed in each side face.

References

  • AS 3600-2001 Australian Standard, Concrete Structures (incorporating amendment No. 1 and 2)

Printable version

Toolbox

Views

Main Page | Free AutoCAD Blocks | Free Revit Families | Funnies | Drafting Standards | Drafting & CAD Forums | Structural Drafting | Technical Dictionary

Personal tools

MediaWiki